50KW Hybrid Three-Phase Inverter Data Sheet
| Model | HDSX50 |
| Rated Power | 50KW | Input | DC Input Voltage Range | 10.5VDC-15VDC(Single battery voltage) |
| Peak Power(20ms) | 120KVA | AC Input Voltage Range | 380Vac/400Vac±10%(customized 190Vac/200Vac) |
| Battery Voltage | 360V/384V | Output(Battery Mode) | Output Voltage | 380Vac/400Vac±10%(customized 190Vac/200Vac) |
| Size(L*W*Hmm) | 720*575*1275 | Output Wave | Pure sine wave |
| Packing Size(L*W*Hmm) | 785*640*1400 | Operating temperature | -10℃~40℃ |
| N.W.(kg) | 307 | Noise | ≤65dB |
| G.W.(kg)(Wooden Packing) | 340 | Elevation | 2000m(More than derating) |
| Installation Method | Tower | Humidity | 0%~95% ,No condensation |
| Parameter |
| Input | DC Input Voltage Range | 10.5VDC-15VDC(Single battery voltage) |
| AC Input Voltage Range | 380Vac/400Vac±10%(customized 190Vac/200Vac) |
| AC Input Frequency Range | 45Hz-55Hz(50Hz)/ 55Hz-65Hz(60Hz) |
| Max AC charging current | 0-45A(Depending on the model) |
| AC charging method | Three-stage (constant current, constant voltage, floating charge) |
| Phase | 3/N/PE |
| Output | Efficiency(Battery Mode) | ≥85% |
| Output Voltage(Battery Mode) | 380Vac/400Vac±10%(customized 190Vac/200Vac) |
| Output Frequency(Battery Mode) | 50/60Hz ±1% |
| Output Wave(Battery Mode) | Pure Sine Wave |
| Output waveform distortion | Linear load≤3% |
| Efficiency(AC Mode) | >99% |
| Output Voltage(AC Mode) | Conforming to AC input |
| Output Frequency(AC Mode) | Conforming to AC input |
| No load loss(Battery Mode) | ≤1% rated power |
| No load loss(AC Mode) | ≤2%rated power( charger does not work in AC mode) |
| No load loss(Energy saving Mode) | ≤10W |
| Phase | 3/N/PE |
| Battery Type | VRLA Battery | Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage) |
| Customize battery | Charging and discharging parameters of different types of batteries can be customized according to user requirements |
| Protection | Battery undervoltage alarm | 11V(Single battery voltage) |
| Battery undervoltage protection | 10.5V(Single battery voltage) |
| Battery overvoltage alarm | 15V(Single battery voltage) |
| Battery overvoltage protection | 17V(Single battery voltage) |
| Battery overvoltage recovery voltage | 14.5V(Single battery voltage) |
| Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) |
| Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) |
| Temperature protection | >90°C(Shut down output) |
| Alarm | A | Normal working condition, buzzer has no alarm sound |
| B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection |
| C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal |
| Working Mode | Battery First/AC First/Saving Energy Mode |
| Transfer Time | ≤4ms |
| Display | LCD |
| Thermal method | Forced air cooling |
| Communication(Optional) | RS485/APP(WIFI monitoring or GPRS monitoring) |
| Environment | Operating temperature | -10℃~40℃ |
| Storage temperature | -15℃~60℃ |
| Noise | 2000m(More than derating) |
| Elevation | ≤65dB |
| Humidity | 0%~95% ,No condensation |