50KW Hybrid Three-Phase Inverter Data Sheet
Model | HDSX50 |
Rated Power | 50KW | Input | DC Input Voltage Range | 10.5VDC-15VDC(Single battery voltage) |
Peak Power(20ms) | 120KVA | AC Input Voltage Range | 380Vac/400Vac±10%(customized 190Vac/200Vac) |
Battery Voltage | 360V/384V | Output(Battery Mode) | Output Voltage | 380Vac/400Vac±10%(customized 190Vac/200Vac) |
Size(L*W*Hmm) | 720*575*1275 | Output Wave | Pure sine wave |
Packing Size(L*W*Hmm) | 785*640*1400 | Operating temperature | -10℃~40℃ |
N.W.(kg) | 307 | Noise | ≤65dB |
G.W.(kg)(Wooden Packing) | 340 | Elevation | 2000m(More than derating) |
Installation Method | Tower | Humidity | 0%~95% ,No condensation |
Parameter |
Input | DC Input Voltage Range | 10.5VDC-15VDC(Single battery voltage) |
AC Input Voltage Range | 380Vac/400Vac±10%(customized 190Vac/200Vac) |
AC Input Frequency Range | 45Hz-55Hz(50Hz)/ 55Hz-65Hz(60Hz) |
Max AC charging current | 0-45A(Depending on the model) |
AC charging method | Three-stage (constant current, constant voltage, floating charge) |
Phase | 3/N/PE |
Output | Efficiency(Battery Mode) | ≥85% |
Output Voltage(Battery Mode) | 380Vac/400Vac±10%(customized 190Vac/200Vac) |
Output Frequency(Battery Mode) | 50/60Hz ±1% |
Output Wave(Battery Mode) | Pure Sine Wave |
Output waveform distortion | Linear load≤3% |
Efficiency(AC Mode) | >99% |
Output Voltage(AC Mode) | Conforming to AC input |
Output Frequency(AC Mode) | Conforming to AC input |
No load loss(Battery Mode) | ≤1% rated power |
No load loss(AC Mode) | ≤2%rated power( charger does not work in AC mode) |
No load loss(Energy saving Mode) | ≤10W |
Phase | 3/N/PE |
Battery Type | VRLA Battery | Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage) |
Customize battery | Charging and discharging parameters of different types of batteries can be customized according to user requirements |
Protection | Battery undervoltage alarm | 11V(Single battery voltage) |
Battery undervoltage protection | 10.5V(Single battery voltage) |
Battery overvoltage alarm | 15V(Single battery voltage) |
Battery overvoltage protection | 17V(Single battery voltage) |
Battery overvoltage recovery voltage | 14.5V(Single battery voltage) |
Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) |
Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) |
Temperature protection | >90°C(Shut down output) |
Alarm | A | Normal working condition, buzzer has no alarm sound |
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection |
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal |
Working Mode | Battery First/AC First/Saving Energy Mode |
Transfer Time | ≤4ms |
Display | LCD |
Thermal method | Forced air cooling |
Communication(Optional) | RS485/APP(WIFI monitoring or GPRS monitoring) |
Environment | Operating temperature | -10℃~40℃ |
Storage temperature | -15℃~60℃ |
Noise | 2000m(More than derating) |
Elevation | ≤65dB |
Humidity | 0%~95% ,No condensation |